{"product_id":"endress-hauser-promass-e-300-coriolis-mass-flowmeter-8e3b","title":"Endress+Hauser Promass E 300 Coriolis Mass Flowmeter 8E3B","description":"\u003cdiv id=\"tech-spec\"\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"related-title\"\u003eTechnical Data\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eDensity\u003c\/h3\u003e\n\u003cdiv class=\"tech-spec-wrap\"\u003e\n\u003ctable class=\"tech-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMeasuring Principle\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eCoriolis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eProduct Headline\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eFlowmeter with minimized total cost of ownership and a compact, easily accessible transmitter.\u003cbr\u003eAccurate measurement of liquids and gases for a wide range of standard applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eSensor features\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eCost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-\/outlet run needs.\u003cbr\u003eCompact dual-tube sensor. Medium temperature up to +150 °C (+302 °F).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eTransmitter features\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eFull access to process and diagnostic information – numerous, freely combinable I\/Os and fieldbuses. Reduced complexity and variety – freely configurable I\/O functionality. Integrated verification – Heartbeat Technology.\u003cbr\u003eProcess pressure up to 100 bar (1450 psi). Compact dual-compartment housing with up to 3 I\/Os. Backlit display with touch control and WLAN access.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eDensity\/Concentration\u003c\/h3\u003e\n\u003cdiv class=\"tech-spec-wrap\"\u003e\n\u003ctable class=\"tech-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMeasuring Principle\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eCoriolis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eProduct headline\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eFlowmeter with minimized total cost of ownership and a compact, easily accessible transmitter.\u003cbr\u003eAccurate measurement of liquids and gases for a wide range of standard applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eSensor features\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eCost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-\/outlet run needs.\u003cbr\u003eCompact dual-tube sensor. Medium temperature up to +150 °C (+302 °F).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eTransmitter features\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eFull access to process and diagnostic information – numerous, freely combinable I\/Os and fieldbuses. Reduced complexity and variety – freely configurable I\/O functionality. Integrated verification – Heartbeat Technology.\u003cbr\u003eProcess pressure up to 100 bar (1450 psi). Compact dual-compartment housing with up to 3 I\/Os. Backlit display with touch control and WLAN access.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eNominal diameter range\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eDN 8 to 80 (⅜ to 3\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eWetted materials\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eMeasuring tube: 1.4539 (904L)\u003cbr\u003eConnection: 1.4404 (316\/316L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMeasured variables\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eMass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMax. measurement error\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eMass flow (liquid): ±0.15 % (standard), ±0.10 % (option)\u003cbr\u003eVolume flow (liquid): ±0.15 %\u003cbr\u003eMass flow (gas): ±0.50 %\u003cbr\u003eDensity (liquid): ±0.0005 g\/cm³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e0 to 180 000 kg\/h (0 to 6615 lb\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMax. process pressure\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003ePN 100, Class 600, 63K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMedium temperature range\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e–40 to +150 °C (–40 to +302 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eAmbient temperature range\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eStandard: –40 to +60 °C (–40 to +140 °F)\u003cbr\u003eOption: –50 to +60 °C (–58 to +140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eSensor housing material\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e1.4301 (304), corrosion resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eTransmitter housing material\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eAlSi10Mg, coated; stainless steel for hygenic transmitter design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eStandard: IP66\/67, Type 4X enclosure\u003cbr\u003eIP69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eDisplay\/Operation\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e4-line backlit display with touch control (operation from outside)\u003cbr\u003eConfiguration via local display and operating tools possible\u003cbr\u003eRemote display available\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eOutputs\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e3 outputs:\u003cbr\u003e4-20 mA HART (active\/passive)\u003cbr\u003e4-20 mA WirelessHART\u003cbr\u003e4-20 mA (active\/passive)\u003cbr\u003ePulse\/frequency\/switch output (active\/passive)\u003cbr\u003eDouble pulse output (active\/passive)\u003cbr\u003eRelay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eInputs\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eStatus input\u003cbr\u003e4-20 mA input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eDigital communication\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eHART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet\/IP, OPC-UA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003ePower supply\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eDC 24 V\u003cbr\u003eAC 100 to 230 V\u003cbr\u003eAC 100 to 230 V \/ DC 24 V (non-hazardous area)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eHazardous area approvals\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eProduct safety\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eCE, C-tick, EAC marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eFunctional safety\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMetrological approvals and certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eCalibration performed on accredited calibration facilities (acc. to ISO\/IEC 17025)\u003cbr\u003eHeartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMarine approvals and certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eLR approval, DNV approval, ABS approval, BV approval, CCS approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003ePressure approvals and certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003ePED, CRN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMaterial certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e3.1 material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eHygienic approvals and certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e3-A, EHEDG, cGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eGas\u003c\/h3\u003e\n\u003cdiv class=\"tech-spec-wrap\"\u003e\n\u003ctable class=\"tech-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMeasuring Principle\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eCoriolis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eProduct headline\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eFlowmeter with minimized total cost of ownership and a compact, easily accessible transmitter.\u003cbr\u003eAccurate measurement of liquids and gases for a wide range of standard applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eSensor features\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eCost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-\/outlet run needs.\u003cbr\u003eCompact dual-tube sensor. Medium temperature up to +150 °C (+302 °F).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eTransmitter features\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eFull access to process and diagnostic information – numerous, freely combinable I\/Os and fieldbuses. Reduced complexity and variety – freely configurable I\/O functionality. Integrated verification – Heartbeat Technology.\u003cbr\u003eProcess pressure up to 100 bar (1450 psi). Compact dual-compartment housing with up to 3 I\/Os. Backlit display with touch control and WLAN access.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eNominal diameter range\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eDN 8 to 80 (⅜ to 3\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eWetted materials\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eMeasuring tube: 1.4539 (904L)\u003cbr\u003eConnection: 1.4404 (316\/316L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMeasured variables\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eMass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMax. measurement error\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eMass flow (liquid): ±0.15 % (standard), ±0.10 % (option)\u003cbr\u003eVolume flow (liquid): ±0.15 %\u003cbr\u003eMass flow (gas): ±0.50 %\u003cbr\u003eDensity (liquid): ±0.0005 g\/cm³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e0 to 180 000 kg\/h (0 to 6615 lb\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMax. process pressure\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003ePN 100, Class 600, 63K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMedium temperature range\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e–40 to +150 °C (–40 to +302 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eAmbient temperature range\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eStandard: –40 to +60 °C (–40 to +140 °F)\u003cbr\u003eOption: –50 to +60 °C (–58 to +140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eSensor housing material\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e1.4301 (304), corrosion resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eTransmitter housing material\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eAlSi10Mg, coated; stainless steel for hygenic transmitter design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eStandard: IP66\/67, Type 4X enclosure\u003cbr\u003eIP69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eDisplay\/Operation\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e4-line backlit display with touch control (operation from outside)\u003cbr\u003eConfiguration via local display and operating tools possible\u003cbr\u003eRemote display available\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eOutputs\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e3 outputs:\u003cbr\u003e4-20 mA HART (active\/passive)\u003cbr\u003e4-20 mA WirelessHART\u003cbr\u003e4-20 mA (active\/passive)\u003cbr\u003ePulse\/frequency\/switch output (active\/passive)\u003cbr\u003eDouble pulse output (active\/passive)\u003cbr\u003eRelay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eInputs\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eStatus input\u003cbr\u003e4-20 mA input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eDigital communication\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eHART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet\/IP, OPC-UA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003ePower supply\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eDC 24 V\u003cbr\u003eAC 100 to 230 V\u003cbr\u003eAC 100 to 230 V \/ DC 24 V (non-hazardous area)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eHazardous area approvals\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eProduct safety\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eCE, C-tick, EAC marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eFunctional safety\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMetrological approvals and certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eCalibration performed on accredited calibration facilities (acc. to ISO\/IEC 17025)\u003cbr\u003eHeartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMarine approvals and certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eLR approval, DNV approval, ABS approval, BV approval, CCS approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003ePressure approvals and certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003ePED, CRN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMaterial certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e3.1 material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eHygienic approvals and certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e3-A, EHEDG, cGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eLiquids\u003c\/h3\u003e\n\u003cdiv class=\"tech-spec-wrap\"\u003e\n\u003ctable class=\"tech-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMeasuring Principle\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eCoriolis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eProduct headline\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eFlowmeter with minimized total cost of ownership and a compact, easily accessible transmitter.\u003cbr\u003eAccurate measurement of liquids and gases for a wide range of standard applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eSensor features\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eCost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-\/outlet run needs.\u003cbr\u003eCompact dual-tube sensor. Medium temperature up to +150 °C (+302 °F).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eTransmitter features\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eFull access to process and diagnostic information – numerous, freely combinable I\/Os and fieldbuses. Reduced complexity and variety – freely configurable I\/O functionality. Integrated verification – Heartbeat Technology.\u003cbr\u003eProcess pressure up to 100 bar (1450 psi). Compact dual-compartment housing with up to 3 I\/Os. Backlit display with touch control and WLAN access.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eNominal diameter range\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eDN 8 to 80 (⅜ to 3\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eWetted materials\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eMeasuring tube: 1.4539 (904L)\u003cbr\u003eConnection: 1.4404 (316\/316L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMeasured variables\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eMass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMax. measurement error\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eMass flow (liquid): ±0.15 % (standard), ±0.10 % (option)\u003cbr\u003eVolume flow (liquid): ±0.15 %\u003cbr\u003eMass flow (gas): ±0.50 %\u003cbr\u003eDensity (liquid): ±0.0005 g\/cm³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e0 to 180 000 kg\/h (0 to 6615 lb\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMax. process pressure\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003ePN 100, Class 600, 63K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMedium temperature range\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e–40 to +150 °C (–40 to +302 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eAmbient temperature range\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eStandard: –40 to +60 °C (–40 to +140 °F)\u003cbr\u003eOption: –50 to +60 °C (–58 to +140 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eSensor housing material\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e1.4301 (304), corrosion resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eTransmitter housing material\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eAlSi10Mg, coated; stainless steel for hygenic transmitter design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eStandard: IP66\/67, Type 4X enclosure\u003cbr\u003eIP69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eDisplay\/Operation\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e4-line backlit display with touch control (operation from outside)\u003cbr\u003eConfiguration via local display and operating tools possible\u003cbr\u003eRemote display available\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eOutputs\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e3 outputs:\u003cbr\u003e4-20 mA HART (active\/passive)\u003cbr\u003e4-20 mA WirelessHART\u003cbr\u003e4-20 mA (active\/passive)\u003cbr\u003ePulse\/frequency\/switch output (active\/passive)\u003cbr\u003eDouble pulse output (active\/passive)\u003cbr\u003eRelay output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eInputs\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eStatus input\u003cbr\u003e4-20 mA input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eDigital communication\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eHART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet\/IP, OPC-UA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003ePower supply\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eDC 24 V\u003cbr\u003eAC 100 to 230 V\u003cbr\u003eAC 100 to 230 V \/ DC 24 V (non-hazardous area)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eHazardous area approvals\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eProduct safety\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eCE, C-tick, EAC marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eFunctional safety\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eFunctional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMetrological approvals and certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eCalibration performed on accredited calibration facilities (acc. to ISO\/IEC 17025)\u003cbr\u003eHeartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMarine approvals and certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eLR approval, DNV approval, ABS approval, BV approval, CCS approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003ePressure approvals and certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003ePED, CRN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMaterial certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e3.1 material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eHygienic approvals and certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003e3-A, EHEDG, cGMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eSteam\u003c\/h3\u003e\n\u003cdiv class=\"tech-spec-wrap\"\u003e\n\u003ctable class=\"tech-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMeasuring Principle\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eCoriolis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eProduct headline\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eFlowmeter with minimized total cost of ownership and a compact, easily accessible transmitter.\u003cbr\u003eAccurate measurement of liquids and gases for a wide range of standard applications.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tech-spec-k\"\u003eMarine approvals and certificates\u003c\/td\u003e\n\u003ctd class=\"tech-spec-v\"\u003eLR approval, DNV approval, ABS approval, BV approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"rich-content\"\u003e\n\u003cp\u003eThe Promass E is robust and is an economical solution for long-term use in high-precision liquid and gas measurement in various standard applications across different industries. Combined with the compact transmitter, the Promass E 300 offers flexible operation and easy system integration: wiring on the same side of the instrument, remote display and improved connection options. Heartbeat Technology ensures compliance at all times and guarantees process safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003cbr\u003eEconomical: versatile instrument; preferred alternative to conventional volumetric flowmeters\u003cbr\u003eFewer process measuring points: multivariable measurement (flow, density, temperature)\u003cbr\u003eSpace-saving installation: no inlet\/outlet straight run requirement\u003cbr\u003eComplete view of process and diagnostic information: various user-configurable input\/output combinations and fieldbuses\u003cbr\u003eReduced complexity and diversity: user-configurable input\/output functions\u003cbr\u003eIntegrated verification: built-in Heartbeat Technology\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003eThe measuring principle is unaffected by the physical properties of the fluid (e.g. viscosity and density).\u003cbr\u003eHigh-precision measurement of liquids and gases in standard applications, with broad applicability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDevice features\u003c\/strong\u003e\u003cbr\u003eCompact dual measuring tube sensor\u003cbr\u003eMedium temperature: max. +150 °C (+302 °F)\u003cbr\u003eProcess pressure: max. 100 bar (1450 psi)\u003cbr\u003eCompact dual-compartment housing with up to 3 inputs\/outputs\u003cbr\u003eBacklit display, touch key operation and WLAN access\u003cbr\u003eRemote display unit available\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":54545385717944,"sku":"8E3B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0950\/7418\/9496\/files\/Endress_HauserPromassE300CoriolisMassFlowmeterBE3B.jpg?v=1793071916","url":"https:\/\/www.njyt-auto.com\/zh\/products\/endress-hauser-promass-e-300-coriolis-mass-flowmeter-8e3b","provider":"NJYT Auto","version":"1.0","type":"link"}