{"product_id":"endress-hauser-proline-promag-w-500-electromagnetic-flowmeter","title":"Endress+Hauser Proline Promag W 500 Electromagnetic Flowmeter for Water \u0026 Wastewater","description":"\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEndress+Hauser Proline Promag W 500\u003c\/strong\u003e is a premium electromagnetic flowmeter designed specifically for demanding water and wastewater applications. It offers reliable, pressure-loss-free measurement with IP68 protection, remote configuration, and Heartbeat Technology, making it ideal for municipal, industrial, and custody transfer projects.\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eKey advantages\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Unmatched range for water applications:\u003c\/strong\u003e Covers DN 25 to 3000 (1\" to 120\") with a measuring range up to 263,000 m³\/h, suitable for large-scale water and wastewater systems.\u003cbr\u003e\u003cstrong\u003e2. IP68 protection for harsh environments:\u003c\/strong\u003e Rated IP68 (Type 6P) with EN ISO 12944 corrosion protection, approved for underground or underwater installations.\u003cbr\u003e\u003cstrong\u003e3. Custody transfer accuracy:\u003c\/strong\u003e Meets MI-001\/OIML R49 standards with ±0.2% optional accuracy, ideal for billing and custody transfer applications.\u003cbr\u003e\u003cstrong\u003e4. Flexible remote configuration:\u003c\/strong\u003e Supports up to 4 I\/Os with freely combinable fieldbuses and WLAN access, enabling easy integration and remote monitoring.\u003cbr\u003e\u003cstrong\u003e5. Drinking water compliant:\u003c\/strong\u003e Features international drinking water approvals (ACS, NSF 61, WRAS), safe for use in potable water distribution networks.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth align=\"left\"\u003eParameter\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMeasuring principle\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eElectromagnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eNominal diameter range\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eDN 25 to 3000 (1\" to 120\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMax. process pressure\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ePN 40, Class 300, 20K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMax. medium temperature (hard rubber liner)\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e+80 °C (+176 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMax. medium temperature (polyurethane liner)\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e+50 °C (+122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMax. medium temperature (PTFE liner)\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e+90 °C (+194 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMax. measurement error (standard)\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e±0.5% o.r. ± 1 mm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMax. measurement error (option)\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e±0.2% o.r. ± 2 mm\/s (Flat Spec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.5 m³\/h to 263000 m³\/h (2.5 gal\/min to 1665 Mgal\/d)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eWetted liner materials\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eHard rubber, polyurethane, PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eWetted electrode materials\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1.4435 (316L), Alloy C22, Tantalum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMeasured variables\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eVolume flow, conductivity, mass flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eDigital communication\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eHART, PROFIBUS DP\/PA, FOUNDATION Fieldbus, Modbus, PROFINET, Ethernet\/IP, OPC-UA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eIP66\/67 (Type 4X), IP68 (Type 6P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eHazardous area approvals\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC, JPN, UK Ex, KC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":53422596128952,"sku":"5W5B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0950\/7418\/9496\/files\/Endress_HauserProlinePromagW500ElectromagneticFlowmeter5W5B_e0952e0d-351c-4eb7-823b-daac07718569.jpg?v=1777527108","url":"https:\/\/www.njyt-auto.com\/products\/endress-hauser-proline-promag-w-500-electromagnetic-flowmeter","provider":"NJYT Auto","version":"1.0","type":"link"}