{"product_id":"endress-hauser-proline-promag-p-10-electromagnetic-flowmeter","title":"Endress+Hauser Proline Promag P 10 Electromagnetic Flowmeter for Basic Process Applications","description":"\u003ch2\u003eIntroduction\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEndress+Hauser Proline Promag P 10\u003c\/strong\u003e is a cost-effective electromagnetic flowmeter built for basic process applications with corrosive liquids. Featuring a user-friendly design, SmartBlue app compatibility, and Heartbeat Technology, it delivers accurate, pressure-loss-free flow measurement with simplified commissioning and maintenance for everyday industrial needs.\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eKey advantages\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Cost-effective \u0026amp; easy operation: \u003c\/strong\u003eDesigned for basic process applications with guided ommissioning and Bluetooth connectivity, simplifying setup and daily use.\u003cbr\u003e\u003cstrong\u003e2. High accuracy for corrosive fluids:\u003c\/strong\u003e Offers ±0.2% o.r. optional accuracy with PFA\/PTFE liners and alloy electrodes, ideal for corrosive liquids in chemical processes.\u003cbr\u003e\u003cstrong\u003e3. No pressure loss \u0026amp; maintenance-free:\u003c\/strong\u003e Full-bore design eliminates pressure drop and moving parts, reducing operational costs and downtime.\u003cbr\u003e\u003cstrong\u003e4. Flexible communication options:\u003c\/strong\u003e Supports HART, Modbus RS485, and IO-Link for seamless integration into various industrial control systems.\u003cbr\u003e\u003cstrong\u003e5. Robust construction with global approvals:\u003c\/strong\u003e IP66\/67 protection and worldwide hazardous area certifications ensure reliable performance in demanding environments.\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth align=\"left\"\u003eParameter\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMeasuring principle\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eElectromagnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eNominal diameter range\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eDN 15 to 600 (½\" to 24\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMax. process pressure\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ePN 40, Class 300, 20K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMax. medium temperature (PFA liner)\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e+150 °C (+302 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMax. medium temperature (PTFE liner)\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e+130 °C (+266 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMax. measurement error (standard)\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e±0.5% o.r. ± 1 mm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMax. measurement error (option)\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e±0.2% o.r. ± 2 mm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e4 dm³\/min to 9600 m³\/h (1 to 44000 gal\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eWetted liner materials\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ePFA, PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eWetted electrode materials\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1.4435 (316L), Alloy C22, Tantalum, Platinum, Titanium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMeasured variables\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eVolume flow, conductivity, mass flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eDigital communication\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eHART, Modbus RS485, IO-Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003ePower supply\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eDC 24 V; AC 100–230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eDegree of protection\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eIP66\/67, Type 4X enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eHazardous area approvals\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eATEX, IECEx, cCSAus, EAC, NEPSI, INMETRO, KC, JPN, UK Ex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Endress+Hauser","offers":[{"title":"Default Title","offer_id":53422452834488,"sku":"5PBB","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0950\/7418\/9496\/files\/Endress_HauserProlinePromagP10ElectromagneticFlowmeter.jpg?v=1777518942","url":"https:\/\/www.njyt-auto.com\/products\/endress-hauser-proline-promag-p-10-electromagnetic-flowmeter","provider":"NJYT Auto","version":"1.0","type":"link"}